M-Bus Slave Click

Price:
Sale price A$26.40   Inc. GST
SKU:
MIKROE-4137
Out Of Stock

We will notify you when this product becomes available.

How does it work?

M-Bus is a bus system used for the remote reading of gas, water, heat, electricity, etc. It also supports various sensors and actuators. This is a cost-optimized bus for the transfer of energy consumption data since it is made for communication on only two wires. M-Bus can be used in the industry, but also, it’s convenient to be used in private households. By the standard, M-Bus master can read up to 250 slave devices. They can be meters, water, electrical, or gas meters. You can also use M-bus in applications like alarm systems, flexible illumination installations, heating control, etc. It can monitor different consumption meters, and it can monitor any leakage.

m-bus Slave click inner image

One of the biggest advantages of M-Bus are:

  • All data reading is accomplished remotely.
  • It is a very simple protocol – it uses only two wires, and it uses power supply from the users which are connected to the wire.
  • Reading errors are minimal. Also, reading is very fast. Further processing is very easy since the received data is presented in a machine readable form.
  • There are no special cables – you can use a telephone cable. With that one cable, you can attach all the meters in the housing with all the meters individually addressable. This way you can have control over each consumption meter while using only one connection cable.

M-Bus Slave Click uses the TSS721A, a single chip transceiver developed for Meter-Bus standard (EN1434-3) applications. The connection to the bus is polarity independent and serves as a slave node in the system. M-Bus Slave Click has full galvanic isolation with optocouplers to improve the reliability of the whole circuit. The circuit is supplied by the master via the bus. The benefit of the TSS721A in M-Bus slaves is the reduction of the number of components needed, and therefore the cost of slaves. Apart from the transmission and reception of data by the M-Bus specification, this IC also provides translation from and to the operating voltage of the microprocessor to which it is connected, to be able to communicate with it. The communication can take place at baudrates from 300 to 9600 Baud. Additional features include integrated protection against reversed polarity, a constant 3.3V power supply for the microprocessor, and the prompt indication of failure of the bus voltage.

Specifications

TypeRS232
ApplicationsRemote sensor reading, remote control over M-Bus
On-board modulesM-Bus Slave Click uses the TSS721A IC, a single chip transceiver developed for Meter-Bus standard, from Texas Instruments
Key FeaturesGalvanically isolated, Slave node
InterfaceUART
CompatibilitymikroBUS
Click board sizeM (42.9 x 25.4 mm)
Input Voltage3.3V

Pinout diagram

This table shows how the pinout on M-Bus Slave Click corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).

NotesPinMikrobus logo.pngPinNotes
 NC1ANPWM16NC 
 NC2RSTINT15NC 
 NC3CSRX14TXUART TX
 NC4SCKTX13RXUART RX
 NC5MISOSCL12NC 
 NC6MOSISDA11NC 
Power Supply3.3V73.3V5V10NC 
GroundGND8GNDGND9GNDGround

Onboard settings and indicators

LabelNameDefault Description
LD1PWR-Power LED Indicator

M-Bus Slave Click electrical specifications

DescriptionMinTypMaxUnit
Supply Voltage-0.33.33.5V
M-Bus Voltage Level-50-50V
Operating Temperature Range-55-85°C

Software Support

We provide a library for the M-Bus Click on our LibStock page, as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Library Description

The library covers all the necessary functions to control M-Bus Slave Click board. Library performs a standard UART interface communication.

Key functions:

  • void mbus_write_byte ( uint8_t input ) - Write Single Byte.
  • uint8_t mbus_read_byte( void ) - Read Single Byte.
  • uint8_t mbus_byte_ready ( void ) - Check for new byte received.

Examples description

The application is composed of three sections :

  • System Initialization - Initializes peripherals.
  • Application Initialization - Initializes UART serial interface and app mode.
  • Application Task - (code snippet) This is an example that demonstrates the use of the M-BUS Click board. In this example, depending on the app mode selected, we send ( receive ) a message to ( from ) the M-BUS Master Click which is connected via cable to M-BUS Click ( slave ). Results are being sent to the Usart Terminal where you can track their changes. All data logs write on USB uart changes approximately for every 2 sec.
void application_task ( ){    char tmp;    uint8_t drdy_flag;    if ( app_mode == APP_MODE_RECEIVER )    {        // RECEIVER - UART polling         drdy_flag = mbus_byte_ready( );        if ( 1 == drdy_flag )        {            tmp = mbus_read_byte( );            mikrobus_logWrite( &tmp, _LOG_BYTE );        }    }    else    {        // TRANSMITER - TX each 2 sec              for ( tmp = 0; tmp < 9; tmp++ )        {            mbus_write_byte( demo_message_data[ tmp ] );            mikrobus_logWrite( " >> MESSAGE SENT <<", _LOG_LINE );            Delay_ms( 100 );        }                Delay_ms( 2000 );    }}

The full application code, and ready to use projects can be found on our LibStock page.

Other mikroE Libraries used in the example:

  • UART

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 click or RS232 click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all MikroElektronika compilers, or any other terminal application of your choice, can be used to read the message.

mikroSDK

This Click board™ is supported with mikroSDK - MikroElektronika Software Development Kit. To ensure proper operation of mikroSDK compliant Click board™ demo applications, mikroSDK should be downloaded from the LibStock and installed for the compiler you are using.

For more information about mikroSDK, visit the official page.

Shipping rates Australia wide and New Zealand

Please add the items in cart and proceed to checkout to calculate shipping cost. We have range of shipping options once goods are ready to dispatch. 
1. Regular shipping: Goods will be shipped using Australia post regular shipping service. 
2. Express shipping: Goods will be shipped using Australia post EXPRESS shipping service. 
3. Express split shipping: Local stock from Melbourne will be shipped ASAP (1 business day) using EXPRESS shipment while remaining items from overseas stock when arrived in Melbourne shipped using second EXPRESS shipment. 
4. Pick up from Thomastown, Melbourne is available on appointment between 9 am to 3 pm during business days. 

  

FAQ:

  • How do I estimate shipping for my order?
    • Add products in the shopping cart and head to the checkout page to estimate the shipping.

Dispatch time

Unless expressly agreed otherwise with you, we will not commence delivery of an order until we have received cleared payment of the purchase price in full.

All orders placed before 11 am AEST (Monday to Friday) will ordinarily be processed on the same day.

We will endeavour to ship the Products by the applicable time indicated on the website, but all times are indicative only.  All shipping times are dispatch times only, and actual delivery dates will depend on the shipping method chosen, delivery address and delivery service provider. 

Note- Please make a note during purchase if you require any item urgently. However we cannot guarantee that we will be able to comply with any request

*Go to Australia post delivery time calculation to get various Australia post service in your area please use our shipping postcode Thomastown, 3074 as the "from" address - https://auspost.com.au/parcels-mail/delivery-times.html?ilink=tools-open-deliv-times.

Shipping Destinations

We ship all products throughout mainland Australia, Tasmania and New Zealand - Including Darwin, Melbourne, Sydney, Tasmania, Adelaide, Brisbane, Perth, all metro and regional areas but do not deliver to areas in Australia where the Australia Post delivery network is not available. 

Check Express shipping delivery coverage area at - http://auspost.com.au/parcels-mail/delivery-areas.html

Receipt of deliveries

Deliveries to post office boxes are not permitted where delivery is by courier. If delivery is by courier and nobody is available at the delivery address to accept delivery when delivery is attempted then the courier may either:

  • leave the relevant parcel at the unattended address (the courier will do so if specified in your delivery requirements); or
  • re-attempt delivery at a later time or date, in which case we may charge you an additional re-delivery fee. 

Note that if a delivery is left unattended at the shipping address and is subsequently stolen then the theft is your responsibility, not ours.

Payment & Security

Apple Pay Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like